Configuration Options (x): None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics
HOME | PRODUCTS | TECHNICAL RESOURCES | BROCHURES |
![]() |
![]() |
![]() |
Terms |
![]() |
|
|
Call: +1 949-251-1800
Email: sales@pacificpower.com Pay your Utility Bill |
Home
|
Products ▼
|
Applications ▼
|
Company ▼
|
Testimonials
|
Support
|
Blog
|
Contact
|
This series consists of several system configurations to accommodate both single and three phase compliance testing at a wide range of power levels from 750VA to 100kVA. for EUT’s than can put power back on the AC utility grid, the AZX Series based ECTS2-Z models are recommended.
All ECTS2 system use the same IEC 61000-3-XX Power Line Harmonics and Flicker Emissions and IEC 61000-4-XX Power Line Immunity test software.
For questions regarding the EMC Compliance Test Systems and or custom solutions, please contact us directly or try our live chat.
Emissions:
IEC 61000-3-2 Harmonics and Inter Harmonics to 16A/phase
IEC 61000-3-12 Harmonics and Inter Harmonics to 75A/phase
IEC 61000-3-3 Flicker to 16A/phase
IEC 61000-3-11 Flicker to 75A/phase
Immunity
IEC 61000-4-11 AC Voltage Dips, Interruptions and Variations to 16A/phase
IEC 61000-4-13 Interharmonics
IEC 61000-4-14 AC Voltage Fluctuations
IEC 61000-4-17 DC Ripple
IEC 61000-4-27 AC Voltage Unbalance three phase
IEC 61000-4-28 Frequency Variations
IEC 61000-4-29 DC Voltage Dips, Interruptions and Variations (Pre-compliance)
IEC 61000-4-34 AC Voltage Dips, Interruptions and Variations to 75A/phase
The ECTS2 systems provide a comprehensive and cost effective solution for all of your EMC compliance testing needs!
Model | Rated Power (VA) | Output Form | Output Volts-Max (VRMS) | Output Amps (Arms) | Input Power Form | Cabinet Height (U) |
---|---|---|---|---|---|---|
Single Phase Systems | ||||||
ECTS2-108M-x | 750 | -n1Ø | 135/270 | 6/3 | 1Ø | n/a |
ECTS2-140M-x | 4000 | 1Ø | 135/270 | 32/16 | 3Ø | 18 |
ECTS2-160M-x | 6000 | 1Ø | 135/270 | 48/16 | 3Ø | 18 |
Configuration Options (x): None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics
Model | Rated Power (VA) | Output Form | Output Volts-Max (Vrms LN) | Output Current @ 230Vac | Input Power Form | Cabinet Height (U) |
---|---|---|---|---|---|---|
Three Phase Systems | ||||||
ECTS2-360F-x | 6,000 | 1Ø | 333 Vrms LN | 25 Arms | 3Ø | 18U |
ECTS2-3120F-x | 12,000 | 3Ø | 333 Vrms LN | 17.4 Arms | 3Ø | 18U |
ECTS2-3150F-x | 15,000 | 3Ø | 333 Vrms LN | 21.7 Arms | 3Ø | 18U |
ECTS2-3240F-x | 24,000 | 3Ø | 333 Vrms LN | 38.4 Arms | 3Ø | 18U |
ECTS2-3300F-x | 30,000 | 3Ø | 333 Vrms LN | 43.3 Arms | 3Ø | 18U |
ECTS2-3450F-x | 45,000 | 3Ø | 333 Vrms LN | 65.0 Arms | 3Ø | 28U |
ECTS2-3600F-x | 60,000 | 3Ø | 333 Vrms LN | 87.0 Arms | 3Ø | 28U |
ECTS2-3750F-x | 75,000 | 3Ø | 333 Vrms LN | 108 Arms | 3Ø | 36U |
ECTS2-3900F-x | 90,000 | 3Ø | 333 Vrms LN | 130 Arms | 3Ø | 36U |
Configuration Options (x): None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics
Model | Rated Power (VA) | Output Form | Output Volts-Max (Vrms LN) | Output Current @ 230Vac | Input Power Form | Cabinet Height (U) |
---|---|---|---|---|---|---|
Three Phase Systems | ||||||
ECTS2-3300Z-x | 30,000 | 3Ø | 440 Vrms LN | 45.0 Arms | 3Ø | AZX + 28U |
ECTS2-3550Z-x | 55,000 | 3Ø | 440 Vrms LN | 75.0 Arms | 3Ø | AZX + 28U |
ECTS2-31100Z-x | 110,000 | 3Ø | 440 Vrms LN | 150 Arms | 3Ø | 2 x AZX + 28U |
Configuration Options (x): None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics
NOTES
-413
Model | Rated Power (VA) | Output Form | Output Volts-Max (Vrms LN) | Output Current @ 230Vac | Input Power Form | Cabinet Height (U) |
---|---|---|---|---|---|---|
Three Phase Systems | ||||||
ECTS2-3300Z-x | 30,000 | 3Ø | 440 Vrms LN | 45.0 Arms | 3Ø | AZX + 28U |
ECTS2-3500Z-x | 50,000 | 3Ø | 440 Vrms LN | 75.0 Arms | 3Ø | AZX + 28U |
ECTS2-3600Z-x | 60,000 | 3Ø | 440 Vrms LN | 90.0 Arms | 3Ø | 2 x AZX + 28U |
ECTS2-31000Z-x | 100,000 | 3Ø | 440 Vrms LN | 150 Arms | 3Ø | 2 x AZX + 28U |
Configuration Options (x): None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics
The ECTS2 Harmonics and Interhamonics measurement system and associated EMC Software suite meets all requirements for compliance testing to these Harmonics standards.
When combined with the optional EPTS Power transfer switch, the ECTS2 test system meets the requirement for AC Voltage Dip and AC Voltage Unbalance testing.
Optional Inter Harmonics Generator for AFX, AZX or LMX based ECTS2 systems supports testing to IEC 61000-4-13
AC immunity tests support for these standard available on LMX based ECTS2 Systems. AC and DC immunity tests support for these same standards are available on all AFX and AZX based ECTS2 Systems. These four immunity test standards are supported by the Ects_4xxGui software.
Frequency Measurement:
Range: 5 to 20 kHz.
Resolution: 0.05 Hz, 100Hz
Accuracy: 0.01%
Voltage Measurement:
No. of Inputs: HFMM-1: 1 channel / HFMM-3: 3 channels
Range: 500Vrms (1000Vpp)
Accuracy: 0.1% Rdg + 10mV
Current Measurement:
Internal CTs: HFMM-1: 1 / HFMM-3: 3
Range: Multipe ranges, auto ranging
Accuracy: 0.1% Rdg + 3 mA
Phase Measurement:
Range: 0.00° ~ 359.99°
Accuracy: 0.1 ° + (0.2 ° x kHz)
Power Measurement:
Accuracy: 0.15% + 0.5W
Current Crest Factor:
Range: 2 ~ 20 depending on RMS current input level
IEC Modes:
IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11, IEC 61000-3-12
JIS-C 61000-3-2
![]() 140LMX Based 4kVA Single Phase ECTS2-140L H&F Test System |
![]() 3300AFX Based Three Phase ECTS2-3300F H&F System |
![]() 3600AFX Based 60kVA 3 Phase ECTS2-3600F H&F Test System |
![]() 3900AFX Based 90kVA 3 Phase ECTS2-3900F H&F Test System |
![]() 3500AZX Based 50kVA 3 Phase ECTS2-3500Z H&F Test System |
![]() LFZ-3-40 Three Phase Flicker Impedance |