EMC Test Systems – ECTS2 Series

EMC Test Systems – ECTS2 Series


Home  ▶  Products  ▶  EMC Test Systems – ECTS2 Series

ECTS2 Series IEC Harmonics & Flicker Test Systems.

Available for Asia and European Markets.  North America availability early 2024
The Pacific Power Source EMC Compliance Test Systems use a sophisticated Harmonics and Flicker measurement system and newly designed flicker impedance options to support single and three phase IEC 61000-3-XX AC – Power Line Harmonics and Flicker as well as IEC 61000-4-XX AC – Power Line immunity compliance testing of EUTs up to the maximum required current of 75A per phase.

This series consists of several system configurations to accommodate both single and three phase compliance testing at a wide range of power levels from 750VA to 100kVA.  for EUT’s than can put power back on the AC utility grid, the AZX Series based ECTS2-Z models are recommended.

All ECTS2 systems use the same IEC 61000-3-XX Power Line Harmonics and Flicker Emissions and IEC 61000-4-XX Power Line Immunity test software.

 

PPS-ECTS2-3300F_LFZ40_Direct_Front-162x300.jpg

CAProp65_Button-120x61.png

For questions regarding the EMC Compliance Test Systems and or custom solutions, please contact us directly or try our live chat.

Overview
Models Table
Key Features
Applications
Specs
Photos
Brochures & Manuals

Overview

The ECTS2 Series of EMC Compliance Test System allows EMC labs to perform full compliance testing of products to the following IEC standards:

Emissions:
IEC 61000-3-2 Harmonics and Inter Harmonics to 16A/phase
IEC 61000-3-12 Harmonics and Inter Harmonics to 75A/phase
IEC 61000-3-3 Flicker to 16A/phase
IEC 61000-3-11 Flicker to 75A/phase

Immunity
IEC 61000-4-11 AC Voltage Dips, Interruptions and Variations to 16A/phase
IEC 61000-4-13 Interharmonics
IEC 61000-4-14 AC Voltage Fluctuations
IEC 61000-4-17 DC Ripple
IEC 61000-4-27 AC Voltage Unbalance three phase
IEC 61000-4-28 Frequency Variations
IEC 61000-4-29 DC Voltage Dips, Interruptions and Variations (Pre-compliance)
IEC 61000-4-34 AC Voltage Dips, Interruptions and Variations to 75A/phase

The ECTS2 systems provide a comprehensive and cost effective solution for all of your EMC compliance testing needs!

ECTS2_Datasheet.png

CAProp65_Button-120x61.png


Models Table

Single Phase LMX Series AC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (VRMS) Output Amps (Arms) Input Power Form Cabinet Height (U)
Single Phase Systems
ECTS2-108M-x 750 -n1Ø 135/270 6/3 n/a
ECTS2-140M-x 4000 135/270 32/16 18
ECTS2-160M-x 6000 135/270 48/16 18

 

Configuration Options (x):  None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

Three Phase AFX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (Vrms LN) Output Current @ 230Vac Input Power Form Cabinet Height (U)
Three Phase Systems
ECTS2-360F-x 6,000 333 Vrms LN 25 Arms 18U
ECTS2-3120F-x 12,000 333 Vrms LN 17.4 Arms 18U
ECTS2-3150F-x 15,000 333 Vrms LN 21.7 Arms 18U
ECTS2-3240F-x 24,000 333 Vrms LN 38.4 Arms 18U
ECTS2-3300F-x 30,000 333 Vrms LN 43.3 Arms 18U
ECTS2-3450F-x 45,000 333 Vrms LN 65.0 Arms 28U
ECTS2-3600F-x 60,000 333 Vrms LN 87.0 Arms 28U
ECTS2-3750F-x 75,000 333 Vrms LN 108 Arms 36U
ECTS2-3900F-x 90,000 333 Vrms LN 130 Arms 36U

 

Configuration Options (x):  None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

Three Phase Regenerative AZX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (Vrms LN) Output Current @ 230Vac Input Power Form Cabinet Height (U)
Three Phase Systems
ECTS2-3300Z-x 30,000 440 Vrms LN 45.0 Arms AZX + 28U
ECTS2-3550Z-x 55,000 440 Vrms LN 75.0 Arms AZX + 28U
ECTS2-31100Z-x 110,000 440 Vrms LN 150 Arms 2 x AZX + 28U

 

Configuration Options (x):  None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

NOTES

  • Included Hardware: AC Power Source, Measurement System, Lumped Flicker Impedance, Receptacle Panel, System Wiring, Power Input Terminals. Cabinet Height may vary with additional hardware options like EPTS.
  • Included Software: Harmonics & Flicker (Hfa) Software for IEC 61000-3-2 Harmonics and IEC 61000-3-3 Flicker Testing or Harmonics & Flicker (Hfa75) Software for IEC 61000-3-12 Harmonics and IEC 61000-3-11 Flicker Testing -B configurations. Software for IEC 61000-4 AC & DC Immunity Testing on standard configuration. Software for IEC61000-4-13 Interharmonics on -C configurations.

Voltage Dips and Interruptions Electronic Power Transfer  Switch Options

Recommended Options

-413

  • Adds IEC 61000-413 Harmonics and Interharmonics Immunity Test.
  • Includes Interharmonic Generator internal to AC power source and IEC 61000-4-13 Test Sequences

Three Phase Regenerative AZX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (Vrms LN) Output Current @ 230Vac Input Power Form Cabinet Height (U)
Three Phase Systems
ECTS2-3300Z-x 30,000 440 Vrms LN 45.0 Arms AZX + 28U
ECTS2-3500Z-x 50,000 440 Vrms LN 75.0 Arms AZX + 28U
ECTS2-3600Z-x 60,000 440 Vrms LN 90.0 Arms 2 x AZX + 28U
ECTS2-31000Z-x 100,000 440 Vrms LN 150 Arms 2 x AZX + 28U

 

Configuration Options (x):  None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics


Key Features

EMC Test System Key Features

  • AC only or AC and DC Test Systems
  • Single Phase and Three phase Output Modes
  • Regenerative Systems Available (AZX based)
  • Programmable Frequency
  • Current and Power Limit Protection
  • EMC Test Software for Harmonics, Flicker and Immunity
  • Detailed test reports to documents EUT compliance
  • Wide Range of Power Levels Available
  • Lumped Flicker Impedance for Flicker Testing
  • Up to 0-600 VAC L-N / 1000V L-L Output Voltage available
  • Up to ±425Vdc output on AFX and ±650Vdc output on AZX systems
  • 15-1200 Hz (AFX) or 15-1000Hz (AZX) Full Power Bandwidth
  • USB, LAN, GPIB & RS232 Interfaces
  • Transfer Switch Option for IEC 61000-4-11 and -4-34
  • Choice of Cabinet Sizes

Applications


IEC 61000-3-2 & IEC 61000-3-12 Harmonics and Inter Harmonics Emissions Test

The ECTS2 Harmonics and Interhamonics measurement system and associated EMC Software suite meets all requirements for compliance testing to these Harmonics standards.


IEC61000-4-11, IEC61000-4-27, IEC61000-4-34

When combined with the optional EPTS Power transfer switch, the ECTS2 test system meets the requirement for AC Voltage Dip and AC Voltage Unbalance testing.

EPTS Option

PPS-EPTS-100A-3_Front-300x138.jpg

IEC 61000-4-13 Inter Harmonics Testing

Optional Inter Harmonics Generator for AFX, AZX or LMX based ECTS2 systems supports testing to IEC 61000-4-13


IEC61000-4-14, IEC61000-4-17, IEC61000-4-27 (pre-compliance), IEC61000-4-28

AC immunity tests support for these standard available on LMX based ECTS2 Systems. AC and DC immunity tests support for these same standards are available on all AFX and AZX based ECTS2 Systems.  These four immunity test standards are supported by the Ects_4xxGui software.


Specs

Harmonics and Flicker Measurement Module

Frequency Measurement:
Range: 5 to 20 kHz.
Resolution: 0.05 Hz, 100Hz
Accuracy: 0.01%

Voltage Measurement:
No. of Inputs: HFMM-1: 1 channel / HFMM-3: 3 channels
Range: 500Vrms (1000Vpp)
Accuracy: 0.1% Rdg + 10mV

Current Measurement:
Internal CTs: HFMM-1: 1 / HFMM-3: 3
Range: Multipe ranges, auto ranging
Accuracy: 0.1% Rdg + 3 mA

Phase Measurement:
Range: 0.00° ~ 359.99°
Accuracy: 0.1 ° + (0.2 ° x kHz)

Power Measurement:
Accuracy: 0.15% + 0.5W

Current Crest Factor:
Range: 2 ~ 20 depending on RMS current input level

IEC Modes:
IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11, IEC 61000-3-12
JIS-C 61000-3-2


Photos

140LMX Based 4kVA Single Phase ECTS2-140L H&F Test System
140LMX Based 4kVA Single Phase ECTS2-140L H&F Test System 

3300AFX Based Three Phase ECTS2-3300F H&F System
3300AFX Based Three Phase ECTS2-3300F H&F System 

3600AFX Based 60kVA 3 Phase ECTS2-3600F H&F Test System
3600AFX Based 60kVA 3 Phase ECTS2-3600F H&F Test System 

3900AFX Based 90kVA 3 Phase ECTS2-3900F H&F Test System
3900AFX Based 90kVA 3 Phase ECTS2-3900F H&F Test System 

3500AZX Based 50kVA 3 Phase ECTS2-3500Z H&F Test System
3500AZX Based 50kVA 3 Phase ECTS2-3500Z H&F Test System 

LFZ-3-40 Three Phase Flicker Impedance
LFZ-3-40 Three Phase Flicker Impedance 

Three Phase Electronic Power Transfer Switch (EPTS) – 100A/phase
Three Phase Electronic Power Transfer Switch (EPTS) – 100A/phase 


Brochures & Manuals


Product Brochure

Download brochure to review product details.


Technical and Application Assistance

Pacific Power Source's seasoned sales and service team is here to help via chat, email or call 1-800-854-2433 or +1-949-251-1800.

 

 

 











This site uses cookies. By continuing to use this site you are giving us your consent.
For more information, please visit our Terms of use or Cookie Policy Page.
Back to Top