Regenerative AC/DC Load Simulator RLS Series

Regenerative AC/DC Load in 4 Quadrant Operation

6kW up to 21kW in 4U

Constant Power Voltage Range

Frequency up to 1200Hz

High Power Density 21kW in 4U, Programmable Load

Simulate any AC or DC linear, non-linear loads with several emulation modes and the highest degree of flexibility.

Applications

  • EV Charging, V2G, V2X
  • Bidirectional OBCs, EVSEs
  • Smart Grid, Utilities
  • Solar Inverters, ESS
  • Burn-in Testing
  • UPS, PDUs
  • AC Power Sources
  • DC Power Supplies
  • DC to DC Converters
  • HV battery and 12Vdc or 48Vdc / battery discharge regenerative breaking
 
 

Highlights

Options

Regenerative Power

Wide Operating Range

Smallest Footprint

Highest Current

Flexible Configuration

Additional Features

Regenerative Load - RLS Series V-I Profiles AC Mode All Models Q1 Quadrant

AC / DC Load with Constant Power Voltage Range

Accurately simulate the power grid with seamless transition of voltage ranges. A single constant power voltage range for both higher current at lower voltage and higher voltages at lower currents eliminating the need to switch between voltage ranges. This prevents potential disruptions in output power.

RLS More Current vs. Competitor v3

Highest Current Availability for AC Load Simulation

The RLS Regenerative Load Simulator provides a broader range of current eliminating the risk of over or under sizing the power source. This reduces the need for additional capital investment. The diagram to the right illustrates the RLS’s capability to provide 20% more current from 120V to 200V when compared to a typical unit that maxes out at 35A/phase.

4 Quadrant AC DC Regenerative Load - Lagging Current

Full 4 Quadrant Operation for Leading & Lagging Power Flows

Fully test AC & DC Power with Bidirectional, 4 quadrant operation. The programmable AC or DC electronic load has 4-Quadrant capability so both true and apparent power can be drawn with programmable control over power factor, current crest factor, current waveshape etc.

AC and DC Load Emulation Modes-2

Several Emulation Modes for Simulation AC & DC Loads

Regenerative AC/DC Electronic Load capability with both AC and DC operating modes pushes the boundaries of your test environment. Simulate linear and non-linear loads (including rectified), inductive and capacitive loads.

Flexible AC DC Input Configurations

Most Flexible Input Configuration for AC/DC Load Simulation

Simultaneous AC and DC load operation of modes per phase(or channel), and the automatic switching of input modes provides test engineers with a unique capability and the highest degree of flexibility. AC, DC input configurations are available in single, split, three phase and multi-channels with optional isolated neutrals in AC and DC.

SmartSource Suite-Controller

Simplify Testing with Smart Control, Built-In

Get access to SmartSource Suite, our proprietary built-in platform that allows full remote control, development, and execution of test sequences in real-time. Intelligently monitor, control, and manage testing using the intuitive embedded web browser interface on any mobile device

Models Table

Model Rated Power (VA) Output Form Voltage Ranges
(VAC/VDC1)
Current 2
(AAc/ADC2)
Input power form (3) rack height
Bench or Rack Mount Models
360RLS 6000 1,2,3 Ø 350 (L-N)/
500
17.0 / 17.30 4U
390RLS 9000 1,2,3 Ø 350 (L-N)/
500
25.0 / 21.0 4U
3120RLS 12000 1,2,3 Ø 350 (L-N)/
500
34.0 / 21.0 4U
3150RLS 15000 1,2,3 Ø 350 (L-N)/
500
42.0 / 21.0 4U
3180RLS 18000 1,2,3 Ø 350 (L-N)/
500
42.0 / 21.0 4U
3210RLS 21000 1,2,3 Ø 350 (L-N)/
500
42.0 / 21.0 4U
Model Rated Power (VA) Output Form Voltage Ranges
(VAC/VDC1)
Current 2
(AAc/ADC2)
Input power form (3) rack height
Parallel Systems
3240RLS-4 24000 2,3 Ø 350 (L-N)/
500
68.0 / 42.0 15U
3300RLS-4 30000 2,3 Ø 350 (L-N)/
500
84.0 / 42.0 15U
3360RLS-4 36000 2,3 Ø 350 (L-N)/
500
84.0 / 42.0 15U
3420RLS-4 42000 2,3 Ø 350 (L-N)/
500
84.0 / 42.0 15U
3630RLS-4 63000 2,3 Ø 350 (L-N)/
500
126.0 / 63.0 15U
3840RLS-4 84000 2,3 Ø 350 (L-N)/
500
168.0 / 84.0 28U
31050RLS-4 105000 2,3 Ø 350 (L-N)/
500
210.0 / 105.0 28U
31260RLS-4 126000 2,3 Ø 350 (L-N)/
500
252.0 / 126 28U
31470RLS-4 147000 2,3 Ø 350 (L-N)/
500
294.0 / 147 40U
31680RLS-4 168000 2,3 Ø 350 (L-N)/
500
336.0 / 168 40U

NOTES

Brochures & Manuals

Product Brochure:

Download brochure to review product details.

Technical and Application Assistance: