SmartTS – PV Inverter Test System

PV Inverter Test System for IEEE 1547.1 / UL 1741 SB Compliance Testing

Pre-Compliance Testing to IEEE1547.1/ UL1741 SB for certification labs

Power up to 1.1MW+

AC Voltage Range

DC Voltage Range

All-in-1 IEEE 1547.1Test Platform

Designed for Distributed Energy Resource (DER) compliance testing with IEEE 1547.1 and UL 1741SB including PV inverters, V2G and more.

SmartTS-PV PV Inverter Test System 6 kW

Applications

  • Solar PV Inverters, ESS
  • DER Grid Compliance Testing
  • V2G, V2X
  • Smart Grid, Utility Grid
  • Microgrids
  • Test Labs, University Research Labs
  • Pre-Compliance Testing for Certification Labs
  • Interoperability  Testing
 

Highlights

Why SmartTS

All-in-1

Highest Performance

Widest Power Range

Automated Pass/Fail

Built-in Safety

grid compliance testing

De-Risk IEEE 1547.1 Grid Compliance Testing. Accelerate Certification. Validate with Confidence.

As grid interconnection standards continue to evolve, PV inverter manufacturers face increasing pressure to validate complex grid-support behaviors under tightly controlled conditions. Requirements such as IEEE 1547, UL 1741 SB, and EN 50549 demand advanced functionality—voltage ride-through, frequency response, anti-islanding, and reactive power control—tested across a wide range of dynamic grid scenarios.

Traditional test setups—fragmented across multiple instruments and vendors—introduce integration challenges, limit repeatability, and extend certification timelines.

SmartTS™ is a fully integrated, turnkey inverter test system designed to eliminate these constraints—enabling faster validation, reduced risk, and complete certification readiness.

SmartTS-PV PV Inverter Test System 55 kW

SmartTS-PVâ„¢ Inverter Test System Takes You From Compliance Burden to Competitive Advantage

SmartTS-PV™ transforms inverter testing from a bottleneck into a strategic capability. Validate against certification requirements early in the development cycle—reducing downstream risk and rework.

  • Accelerate Time-to-Certification: Pre-validate against global standards before entering third-party labs. Reduce test iterations, avoid scheduling delays, and move through certification with
    confidence.

  • De-Risk Product Development: Simulate abnormal grid conditions safely and repeatably. Identify edge-case failures early—before they become costly redesigns or certification failures.

  • Lower Total Cost of Test: Replace complex, multi-vendor setups with a single integrated platform. Reduce reliance on external labs and minimize engineering overhead.

  • Future-Proof Your Test Capability: Adapt to evolving grid codes and next-generation inverter requirements without re-architecting your lab infrastructure.

Advanced Grid Compliance Testing Capabilities

The SmartTS-PV inverter test system enables testing of critical DER grid support functions below. These tests ensure inverters meet utility interconnection requirements for distributed energy resources.  Pacific Power Source Grid Simulators provide both source and loading capabilities with wide operating ranges, extra current, and robust hardware performance. These capabilities allow engineers to validate real-world performance and grid support functionality under controlled, repeatable conditions.

Anti-Islanding Mode Available - Option P for PV Inverter Testing

The anti-islanding test requirements for Distributed Energy Resources such as PV inverters or bidirectional V2G EV Chargers are mandatory for regulatory approval of these energy producing devices. Option P mode is the built-in anti-islanding test operating mode for Pacific Power Source AZX and GSZ grid simulators.

When enabled, it configures the system to electronically emulate the resonant RLC load required for anti-islanding testing, execute the grid disconnection event, and precisely measure the inverter’s response time using an internal digital storage oscilloscope. This mode allows the grid simulator to function as a complete anti-islanding test system—combining grid simulation, load emulation, and disconnect-time measurement in one platform—without external components, multiple instruments, or custom test software.

IEEE1547.1/ UL1741 SB Quality Logic Software

Simplify Testing with Automated IEEE 1547.1 and UL1741SB Software Tools with QualityLogic

QualityLogic‘s software is pre-installed for testing to IEEE 1547.1 and UL 1741SB. The SmartTS system includes a built-in monitor. Learn how the SmartTS-PV platform simplifies DER grid compliance testingRequest a system demonstration or speak with a testing expert.

Photos

SmartTS-PV PV Inverter Test System 6 kW

6 or 15kVA RGS Regenerative AC & DC Power Source

SmartTS-PV PV Inverter Test System 55 kW

55kVA AZX Regenerative AC & DC Power Source

IEEE1547.1/ UL1741 SB Quality Logic Software

QualityLogic 1547.1 / UL1741 Test Automation Tool

Brochures & Manuals

Product Brochure:

Download brochure to review product details.

Technical and Application Assistance: