Regenerative AC/DC Load Simulator RLS Series

Regenerative AC/DC Load Now 24kW in 4U

Scalable Power up to 1.296MVA/MW

Power up to 1.296MW

Constant Power Voltage Range

Frequency up to 1200Hz

High Power Density 24kW in 4U, Programmable Load

Simulate any AC or DC linear, non-linear loads with several emulation modes and the highest degree of flexibility. Right-sized power; scale power later as needed.

Applications

  • EV Charging, V2G, V2X
  • Bidirectional OBCs, EVSEs
  • Smart Grid, Utilities
  • Solar Inverters, ESS
  • Burn-in Testing
  • UPS, PDUs
  • AC Power Sources
  • DC Power Supplies
  • DC to DC Converters
  • HV battery and 12Vdc or 48Vdc / battery discharge regenerative breaking
 
 

Highlights

Options

Regenerative Power

Wide Operating Range

Smallest Footprint

Highest Current

Flexible Configuration

Additional Features

Regenerative AC load voltage range

AC / DC Load with Constant Power Voltage Range

Accurately simulate the power grid with seamless transition of voltage ranges. A single constant power voltage range for both higher current at lower voltage and higher voltages at lower currents eliminating the need to switch between voltage ranges. This prevents potential disruptions in output power.

AGX RGS RLS Highest Current Availability

Highest Current Availability for AC Load Simulation

The RLS Regenerative Load Simulator provides a broader range of current eliminating the risk of over or under sizing the power source. This reduces the need for additional capital investment. The diagram to the right illustrates the RLS’s capability to provide 20% more current from 120V to 200V when compared to a typical unit that maxes out at 35A/phase.

4 Quadrant AC DC Regenerative Load - Lagging Current

Full 4 Quadrant Operation for Leading & Lagging Power Flows

Fully test AC & DC Power with Bidirectional, 4 quadrant operation. The programmable AC or DC electronic load has 4-Quadrant capability so both true and apparent power can be drawn with programmable control over power factor, current crest factor, current waveshape etc.

Several Emulation Modes for Simulation AC & DC Loads

Regenerative AC/DC Electronic Load capability with both AC and DC operating modes pushes the boundaries of your test environment. Simulate linear and non-linear loads (including rectified), inductive and capacitive loads.

Flexible AC DC Input Configurations

Most Flexible Input Configuration for AC/DC Load Simulation

Simultaneous AC and DC load operation of modes per phase(or channel), and the automatic switching of input modes provides test engineers with a unique capability and the highest degree of flexibility. AC, DC input configurations are available in single, split, three phase and multi-channels with optional isolated neutrals in AC and DC.

SmartSource Suite-Controller

Simplify Testing with Smart Control, Built-In

Get access to SmartSource Suite, our proprietary built-in platform that allows full remote control, development, and execution of test sequences in real-time. Intelligently monitor, control, and manage testing using the intuitive embedded web browser interface on any mobile device

Models Table

Model Rated Power (VA) Output Form Voltage Ranges
(VAC/VDC1)
Current 2
(AAc/ADC2)
rack height
Bench or Rack Mount Models
360RLS 6kVA/kW 1,2,3 Ø 30-350 (L-N)/
±0-475
17.0 / 17.0 4U
390RLS 9kVA/kW 1,2,3 Ø 30-350 (L-N)/
±0-475
25.0 / 21.0 4U
3120RLS 12kVA/kW 1,2,3 Ø 0-350 (L-N)/
±0-475
34.0 / 21.0 4U
3150RLS 15kVA/kW 1,2,3 Ø 30-350 (L-N)/
±0-475
48.0 / 21.0 * 4U
3180RLS 18kVA/kW 1,2,3 Ø 30-350 (L-N)/
±0-475
48.0 / 21.0 * 4U
3210RLS 21kVA/kW 1,2,3 Ø 30-350 (L-N)/
±0-475
48.0 / 21.0 * 4U
3241RLS 24kVA/kW 1,2,3 Ø 30-350 (L-N)/
±0-475
48.0 / 21.0 * 4U

*RMS current up to 48A per phase (45Hz to 200Hz);
Above 200Hz – up to 42.0 Arms / 21.0 Adc per phase in 3 & 2 Phase Mode, and 126 Arms / 63.0Adc in 1 Phase Mode.
.

Model Rated Power (VA) Output Form Voltage Ranges
(VAC/VDC1)
Current 2
(AAc/ADC2)
rack height
Parallel Systems
3300RLS-4UC 30kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
84.0 / 42.0 8U
3360RLS-4UC 36kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
84.0 / 42.0 18U
3481RLS-4UC 48kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
96.0 / 42.0 18U
3630RLS-4UC 63kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
126.0 / 63.0 18U
3721RLS-4UC 72kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
144.0 / 63.0 18U
3961RLS-4UC 96kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
192.0 / 84.0 32U
31050RLS-4UC 105kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
210.0 / 105.0 32U
31201RLS-4UC 120kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
240.0 / 105.0 32U
31441RLS-4UC 144kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
288.0 / 126.0 32U
31681RLS-4UC 168kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
336.0 / 147.0 42U
31921RLS-4UC 192kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
384.0 / 168.0 42U
32161RLS-4UC 216kVA/kW 2,3 Ø 30-350 (L-N)/
±0-475
432.0 / 189.0 42U

NOTES

Current values shown are per phase for 2 or 3 phase mode. In 1 phase, current would be times 3.

Note 1: Rated power shown is for Three Phase or Single Phase mode operation. For Split Phase mode, rated power is 2/3.

Note 2: For Voltages above 350Vac some frequency and Vthd restrictions apply.

Note 3: Above 200Hz max current derates.

Additional Information:

  • • Paralled systems up to 432kVA/kW.
    • Three-Phase high power system configurations available up to 1.296 MVA/MW; Contact Factory for details.