EMC Test Systems – ECTS2 Series

ECTS2 Series IEC Harmonics & Flicker Test Systems

EMC Test

EMC Harmonics, Flicker and Immunity Test System. Available in power levels from 800VA to 100kVA.

For questions regarding the EMC Compliance Test Systems and or custom solutions, please contact us directly

Overview

The ECTS2 Series of EMC Compliance Test System allows EMC labs to perform full compliance testing of products to the following IEC standards:

Emissions:
IEC 61000-3-2 Harmonics and Inter Harmonics to 16A/phase
IEC 61000-3-12 Harmonics and Inter Harmonics to 75A/phase
IEC 61000-3-3 Flicker to 16A/phase
IEC 61000-3-11 Flicker to 75A/phase

Models Table

Single Phase LMX Series AC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (VRMS) Output Amps (Arms) Input Power Form Cabinet Height (U)
Single Phase Systems
ECTS2-108M-x 750 -n1Ø 135/270 6/3 n/a
ECTS2-140M-x 4000 135/270 32/16 18
ECTS2-160M-x 6000 135/270 48/16 18

 

Configuration Options (x):  None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

Three Phase AFX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (Vrms LN) Output Current @ 230Vac Input Power Form Cabinet Height (U)
Three Phase Systems
ECTS2-360F-x 6,000 333 Vrms LN 25 Arms 18U
ECTS2-3120F-x 12,000 333 Vrms LN 17.4 Arms 18U
ECTS2-3150F-x 15,000 333 Vrms LN 21.7 Arms 18U
ECTS2-3240F-x 24,000 333 Vrms LN 38.4 Arms 18U
ECTS2-3300F-x 30,000 333 Vrms LN 43.3 Arms 18U
ECTS2-3450F-x 45,000 333 Vrms LN 65.0 Arms 28U
ECTS2-3600F-x 60,000 333 Vrms LN 87.0 Arms 28U
ECTS2-3750F-x 75,000 333 Vrms LN 108 Arms 36U
ECTS2-3900F-x 90,000 333 Vrms LN 130 Arms 36U

 

Configuration Options (x):  None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

Three Phase Regenerative AZX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (Vrms LN) Output Current @ 230Vac Input Power Form Cabinet Height (U)
Three Phase Systems
ECTS2-3300Z-x 30,000 440 Vrms LN 45.0 Arms AZX + 28U
ECTS2-3550Z-x 55,000 440 Vrms LN 75.0 Arms AZX + 28U
ECTS2-31100Z-x 110,000 440 Vrms LN 150 Arms 2 x AZX + 28U

 

Configuration Options (x):  None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

NOTES

  • Included Hardware: AC Power Source, Measurement System, Lumped Flicker Impedance, Receptacle Panel, System Wiring, Power Input Terminals. Cabinet Height may vary with additional hardware options like EPTS.
  • Included Software: Harmonics & Flicker (Hfa) Software for IEC 61000-3-2 Harmonics and IEC 61000-3-3 Flicker Testing or Harmonics & Flicker (Hfa75) Software for IEC 61000-3-12 Harmonics and IEC 61000-3-11 Flicker Testing -B configurations. Software for IEC 61000-4 AC & DC Immunity Testing on standard configuration. Software for IEC61000-4-13 Interharmonics on -C configurations.

Voltage Dips and Interruptions Electronic Power Transfer  Switch Options

Click here for information on Electronic Power Transfer Switches for Voltage Dips Compliance Test

Recommended Options

-413

  • Adds IEC 61000-413 Harmonics and Interharmonics Immunity Test.
  • Includes Interharmonic Generator internal to AC power source and IEC 61000-4-13 Test Sequences

Three Phase Regenerative AZX Series AC &DC Source Based ECTS2 EMC Test Systems

Model Rated Power (VA) Output Form Output Volts-Max (Vrms LN) Output Current @ 230Vac Input Power Form Cabinet Height (U)
Three Phase Systems
ECTS2-3300Z-x 30,000 440 Vrms LN 45.0 Arms AZX + 28U
ECTS2-3500Z-x 50,000 440 Vrms LN 75.0 Arms AZX + 28U
ECTS2-3600Z-x 60,000 440 Vrms LN 90.0 Arms 2 x AZX + 28U
ECTS2-31000Z-x 100,000 440 Vrms LN 150 Arms 2 x AZX + 28U

 

Configuration Options (x):  None includes Harmonics, Flicker & Immunity Tests; -B = Harmonics & Flicker Test only; -C = Adds IEC61000-4-13 Interharmonics

Key Features

EMC Test System Key Features

  • AC only or AC and DC Test Systems
  • Single Phase and Three phase Output Modes
  • Regenerative Systems Available (AZX based)
  • Programmable Frequency
  • Current and Power Limit Protection
  • EMC Test Software for Harmonics, Flicker and Immunity
  • Detailed test reports to documents EUT compliance
  • Wide Range of Power Levels Available
  • Lumped Flicker Impedance for Flicker Testing
  • Up to 0-600 VAC L-N / 1000V L-L Output Voltage available
  • Up to ±425Vdc output on AFX and ±650Vdc output on AZX systems
  • 15-1200 Hz (AFX) or 15-1000Hz (AZX) Full Power Bandwidth
  • USB, LAN, GPIB & RS232 Interfaces
  • Transfer Switch Option for IEC 61000-4-11 and -4-34
  • Choice of Cabinet Sizes

Applications

IEC 61000-3-2 & IEC 61000-3-12 Harmonics and Inter Harmonics Emissions Test:

The ECTS2 Harmonics and Interhamonics measurement system and associated EMC Software suite meets all requirements for compliance testing to these Harmonics standards.

IEC61000-4-14, IEC61000-4-17, IEC61000-4-27 (pre-compliance), IEC61000-4-28:

AC immunity tests support for these standard available on LMX based ECTS2 Systems. AC and DC immunity tests support for these same standards are available on all AFX and AZX based ECTS2 Systems.  These four immunity test standards are supported by the Ects_4xxGui software.

IEC61000-4-11, IEC61000-4-27, IEC61000-4-34:

When combined with the optional EPTS Power transfer switch, the ECTS2 test system meets the requirement for AC Voltage Dip and AC Voltage Unbalance testing.

EPTS Option

IEC 61000-4-13 Inter Harmonics Testing:

Optional Inter Harmonics Generator for AFX, AZX or LMX based ECTS2 systems supports testing to IEC 61000-4-13

Specs

Harmonics and Flicker Measurement Module

Frequency Measurement:
Range: 5 to 20 kHz.
Resolution: 0.05 Hz, 100Hz
Accuracy: 0.01%

Voltage Measurement:
No. of Inputs: HFMM-1: 1 channel / HFMM-3: 3 channels
Range: 500Vrms (1000Vpp)
Accuracy: 0.1% Rdg + 10mV

Current Measurement:
Internal CTs: HFMM-1: 1 / HFMM-3: 3
Range: Multipe ranges, auto ranging
Accuracy: 0.1% Rdg + 3 mA

Phase Measurement:
Range: 0.00° ~ 359.99°
Accuracy: 0.1 ° + (0.2 ° x kHz)

Power Measurement:
Accuracy: 0.15% + 0.5W

Current Crest Factor:
Range: 2 ~ 20 depending on RMS current input level

IEC Modes:
IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11, IEC 61000-3-12
JIS-C 61000-3-2

Photos

140LMX Based 4kVA Single Phase ECTS2-140L H&F Test System

3300AFX Based Three Phase ECTS2-3300F H&F System

3600AFX Based 60kVA 3 Phase ECTS2-3600F H&F Test System

3900AFX Based 90kVA 3 Phase ECTS2-3900F H&F Test System

3500AZX Based 50kVA 3 Phase ECTS2-3500Z H&F Test System

LFZ-3-40 Three Phase Flicker Impedance

Three Phase Electronic Power Transfer Switch (EPTS) – 100A/phase

Brochures & Manuals

Product Brochure and Application Notes:

Download brochure to review product and application notes..

Technical and Application Assistance:

Pacific Power Source’s seasoned sales and service team is here to help via chat, email or call 1-800-854-2433 or +1-949-251-1800.