ppssmartsource LabVIEW Wrapper Conversion Report

viernes, 27 de marzo de 2026 12:33:45

Source Driver Information
Driver Prefix: ppssmartsource
Total number of functions: 128
Driver Class: IviACPwr

LabVIEW Wrapper Driver Information
Total number of VIs: 111

Conversion Information
Basic

For best results, it is important to ensure that the source driver is fully compliant with the IVI Foundation specifications and all problems relating to the driver and function panel are resolved before running this tool. To help verify IVI compliance and detect possible problems with the driver, use the IVI Specific Driver Test Suite which can be found under Tools menu in LabWindows/CVI.
The following errors/warnings occurred when generating the wrapper for this instrument driver. Address each of these issues to complete the instrument driver VIs. Note that some of these issues may be a result of issues in the LabWindows/CVI driver. To resolve these types of issues, fix the problem in the LabWindows/CVI driver and regenerate the LabVIEW interface. Contact instrument.drivers@ni.com for technical assistance.

Constant Array Size to Allocate Indicator
The following instrument driver VI(s) have string or array indicators. The utility uses a constant to allocate memory for the indicator. Review the block diagrams of the VI(s) to ensure that the appropriate size is allocated for the indicator. The block diagram constant used to allocate array size or string size should be adjusted so that it is large enough to accommodate all valid values for the indicator. If the DLL function in the generated VI(s) has a size parameter, delete the block diagram constant and wire the size control to the size input of the Initialize Array function.
    ppssmartsource Query Program.vi -> Program Data
    ppssmartsource Query Program Catalog.vi -> Program Catalog

Default Menu Palette Icon
Cannot match appropriate icons for the following menu (.mnu) palettes. Assign meaningful icons to the palette(s) by selecting Tools»Advanced»Edit Palette Views. Use the Icon Art Glossary for assistance with creating menu palette icons.
    dir - Configuration - Phase
    dir - Configuration - Protections
    dir - Configuration - Peak Protections
    dir - Configuration - Program Control
    dir - Configuration - Current Source
    dir - Configuration - Constant Resistance Load
    dir - Configuration - Constant Power Load
    dir - Configuration - Circuit Emulation
    dir - Configuration - Protections - Power Protection
    dir - Configuration - Peak Protections - Peak Current Protection
    dir - Configuration - Peak Protections - Peak Voltage Protection
    dir - Configuration - Peak Protections - Peak Power Protection

Default VI Icon
Cannot match appropriate icons for the following VI(s). Assign meaningful icons to the VI(s) by right-clicking the icon in the upper-right corner of the VI(s) and selecting Edit Icon. Use the Icon Art Glossary for assistance with creating VI icons.
    ppssmartsource Configure Voltage Limit.vi
    ppssmartsource Configure Frequency Limit.vi
    ppssmartsource Configure Power Limit.vi
    ppssmartsource Configure KVA Limit.vi
    ppssmartsource Configure Output Frequency.vi
    ppssmartsource Configure Output Mode.vi
    ppssmartsource Configure Initial Output Voltage.vi
    ppssmartsource Configure Transient Auto RMS Enabled.vi
    ppssmartsource Configure PPSC Setup.vi
    ppssmartsource Configure PPSC Slew Rate.vi
    ppssmartsource Configure Operating Mode.vi
    ppssmartsource Configure Load Type.vi
    ppssmartsource Query Output Mode.vi
    ppssmartsource Query Current Limit.vi
    ppssmartsource Configure Peak Current Limit.vi
    ppssmartsource Configure Program.vi
    ppssmartsource Copy Program.vi
    ppssmartsource Clear Memory.vi
    ppssmartsource Delete Program.vi
    ppssmartsource Delete All Programs.vi
    ppssmartsource Execute Program.vi
    ppssmartsource Execute Transient.vi
    ppssmartsource Query Program.vi
    ppssmartsource Query Program Catalog.vi
    ppssmartsource Configure Current Level.vi
    ppssmartsource Configure Current DC Level.vi
    ppssmartsource Configure CS Voltage Limit.vi
    ppssmartsource Configure Resistance Type.vi
    ppssmartsource Configure Resistance Modulation.vi
    ppssmartsource Configure Resistance AC.vi
    ppssmartsource Configure Resistance DC.vi
    ppssmartsource Configure Conductance AC.vi
    ppssmartsource Configure Conductance DC.vi
    ppssmartsource Configure CR Filter Frequency.vi
    ppssmartsource Configure Power Type.vi
    ppssmartsource Configure Power Modulation.vi
    ppssmartsource Configure Power RMS AC.vi
    ppssmartsource Configure Power RMS DC.vi
    ppssmartsource Configure Power KVA AC.vi
    ppssmartsource Configure Power KVA DC.vi
    ppssmartsource Configure Circuit Emulation Type.vi
    ppssmartsource Configure CE Resistence.vi
    ppssmartsource Configure CE Resistence RL.vi
    ppssmartsource Configure CE Resistence RC.vi
    ppssmartsource Configure CE Inductance.vi
    ppssmartsource Configure CE Capacitance.vi
    ppssmartsource Configure CE Capacitance Initial Voltage.vi
    ppssmartsource Configure CE Filter Frequency.vi
    ppssmartsource Configure CE R RsL RsC.vi
    ppssmartsource Configure Power Protection.vi
    ppssmartsource Query Power Protection Tripped.vi
    ppssmartsource Reset Power Protection.vi
    ppssmartsource Configure Over Voltage Protection.vi
    ppssmartsource Configure Under Voltage Protection.vi
    ppssmartsource Query Over Voltage Protection Tripped.vi
    ppssmartsource Query Under Voltage Protection Tripped.vi
    ppssmartsource Reset Over Voltage Protection.vi
    ppssmartsource Reset Under Voltage Protection.vi
    ppssmartsource Configure Peak Current Protection.vi
    ppssmartsource Query Peak Current Protection Tripped.vi
    ppssmartsource Reset Peak Current Protection.vi
    ppssmartsource Configure Peak Voltage Protection.vi
    ppssmartsource Query Peak Voltage Protection Tripped.vi
    ppssmartsource Reset Peak Voltage Protection.vi
    ppssmartsource Configure Peak Power Protection.vi
    ppssmartsource Query Peak Power Protection Tripped.vi
    ppssmartsource Reset Peak Power Protection.vi

Functions Unselected
The following functions are not selected. The LabVIEW Instrument Driver Import Wizard does not generate wrapper VIs for them.
    ppssmartsource_GetError
    ppssmartsource_ClearError
    ppssmartsource_LockSession
    ppssmartsource_UnlockSession
    ppssmartsource_SetAttributeViInt32
    ppssmartsource_SetAttributeViReal64
    ppssmartsource_SetAttributeViString
    ppssmartsource_SetAttributeViBoolean
    ppssmartsource_SetAttributeViSession
    ppssmartsource_GetAttributeViInt32
    ppssmartsource_GetAttributeViReal64
    ppssmartsource_GetAttributeViString
    ppssmartsource_GetAttributeViBoolean
    ppssmartsource_GetAttributeViSession
    ppssmartsource_CheckAttributeViInt32
    ppssmartsource_CheckAttributeViReal64
    ppssmartsource_CheckAttributeViString
    ppssmartsource_CheckAttributeViBoolean
    ppssmartsource_CheckAttributeViSession