HOME | PRODUCTS | TECHNICAL RESOURCES | BROCHURES |
![]() |
![]() |
![]() |
Terms |
![]() |
|
|
Call: +1 949-251-1800
Email: sales@pacificpower.com Pay your Utility Bill |
Home
|
Products ▼
|
Applications ▼
|
Company ▼
|
Testimonials
|
Support
|
Blog
|
Contact
|
For questions regarding the ASX Series and or custom solutions, please contact us directly or try our live chat.
Note: The ASX Series products have been discontinued due to parts obsolescence. For new applications or requirements, see the new LSX Series which offer more features and additional remote control interfaces.
The ASX Series is a family of High Performance Switching AC Power Sources covering the power range from 1.5kVA to 6kVA (1). The product line offers both single and three phase models. Units are conservatively designed and output power ratings are based on the most severe combination of input line, output voltage, power factor, and temperature.
Great emphasis has been placed on low acoustic noise, ease of installation, and maximum power per cubic inch of rack space. Control and operational features provide a high degree of application versatility and ease of use for the test engineer. Applications range from simple, manually controlled frequency conversion to harmonic testing and sophisticated bus programmable transient simulation.
Power conversion within the ASX Series is achieved by high frequency pulse width modulation, resulting in cool, quiet and efficient operation.
Note 1: For requirements higher than 6kVA, see ADF Series and AFX Series.
Model | Rated Power (VA) | Output Form | Output Volts-Max (VRMS) | Output Amps (Arms) | Input Power Form | Panel Height (U) | Weight (Lbs./KG) |
---|---|---|---|---|---|---|---|
1 Phase Model | |||||||
115ASX | 1500 | 1Ø | 132 | 16 | 1Ø | 3 | 65/29.5 |
120ASX | 2000 | 1Ø | 150/300 | 20/14 | 1Ø | 3 | 75/34 |
140ASX | 4000 | 1Ø | 135/270 | 32/16 | 3Ø* | 5 | 120/54.5 |
160ASX | 6000 | 1Ø | 132/264 | 48/16 | 3Ø | 5 | 145/66 |
3 Phase Model | |||||||
315ASX | 1500 | 1Ø 3Ø |
132/264 132 (Vl-N) |
12/6 4 per Ø |
1Ø | 3 | 75/34 |
320ASX | 2000 | 1Ø 3Ø |
150/300 150 (Vl-N) |
20/12 7 per Ø |
1Ø | 3 | 85/38.5 |
345ASX | 4500 | 1Ø 3Ø |
135/270 135 (Vl-N) |
36/12 12 per Ø |
3Ø* | 5 | 145/66 |
360ASX | 6000 | 1Ø 3Ø |
132/264 132 (Vl-N) |
48/16 16 per Ø |
3Ø | 5 | 145/66 |
Model | Power (VA) | Form | Output Volts-Max (VRMS) | Output Amps (ARMS) | Power Form | Height (U) |
Weight (Lbs./KG)
|
||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Single Phase Model | |||||||||||||
Transformer | Transformer | ||||||||||||
Direct | 1.5:1 | 2.0:1 | 2.5:1 | Direct | 1.5:1 | 2.0:1 | 2.5:1 | ||||||
115ASXT | 1500 | 1Ø | 132 | 198 | 264 | 330 | 16 | 10.7 | 8 | 6.4 | 1Ø | 3 | 80/36.4 |
140ASXT | 4000 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 32/16 | 21.3/10.7 | 16/8 | 12.8/6.4 | 3Ø | 8 | 245/111.3 |
160ASXT | 6000 | 1Ø/2Ø | 132/264 | 198/396 | 264/528 | 330/600 | 48/16 | 32/10.6 | 24/8 | 19.2/6.4 | 3Ø | 8 | 270/122.8 |
3 Phase Model | |||||||||||||
Transformer | Transformer | ||||||||||||
Direct | 1.5:1 | 2.0:1 | 2.5:1 | Direct | 1.5:1 | 2.0:1 | 2.5:1 | ||||||
345ASXT |
4500
|
1Ø/2Ø
3Ø
|
135/270
135/234
|
202/404
202/350
|
270/540
270/468
|
338/600
338/585
|
36/12
12/Ø
|
24/8
8/Ø
|
18/6
6/Ø
|
14.4/4.8
4.8/Ø
|
3Ø | 8 | 265/120 |
360ASXT |
6000
|
1Ø/2Ø
3Ø
|
132/264
132/228
|
198/396
198/343
|
264/528
264/457
|
330/600
330/572
|
48/16
16/Ø
|
32/10.7
10.7/Ø
|
24/8
8/Ø
|
19.2/6.4
6.4/Ø
|
3Ø | 8 | 270/122.8 |
NOTES
Provides for exceptional accuracy of the AC output Voltage. When enabled, accuracy improves to ±0.1% referenced to the power source internal voltmeter.
Programmable Output Impedance provides the operator with the ability to dynamically control the output impedance of the AC Power Source. Using the output current term as conditioned feedback signal to the output voltage circuits, positive or negative impedance may be programmed. This control simulates the effects of, or compensates for high peak current, distribution, or transformer losses of up to ±10% of the output voltage.
This feature creates positive, negative, or zero output impedance (Zo).
Up to 22 different waveforms can be stored in the waveform library for execution as part of a steady state program or for substitution in any output phase as part of a transient test program. Memory location #1 is a non-editable high resolution sine wave. Locations 2-22 are editable and can be substituted in any output phase. An unlimited number of waveforms may be stored on the computer for those using a programmable UPC.
A full-featured editor permits modification of a stored waveform in both time and frequency domains. This method can be used to quickly create spikes, dropouts, notches and other sub-cycle wave conditions. The resulting modified waveform is stored for execution in steady-state or transient programs.
Provides both graphic (using LabView for Windows®) and numeric displays of the harmonic structure of a voltage or current waveform. Each waveform is analyzed for its harmonic content up to the 51st harmonic. Amplitude and phase are reported to the local display. The LabVIEWT instrument driver displays numeric values as well as a graphic summary of the harmonic spectrum.
Quickly create virtually any AC test waveform by building it out of harmonics. The process is as simple as keying in the magnitude and phase angle of each desired harmonic up through the 51st. Additionally, waveforms can be created by downloading from a host PC.
Create and execute transients that occur over a specified time segment to modify the output waveform, voltage, and frequency for any or all phases. An output trigger is provided for synchronizing external test equipment to the actual transient event.
Create and execute transients that substitute a waveform in any or all phases for 1 to 100 cycles. The waveform being substituted can be selected and/or modified from the waveform library.
The ASX Series Power Source is equipped with a powerful microcontroller to create a fully integrated test system. It supplies a variety of power conditions to the device under test and meters/analyzes all output performance parameters.
The ASX Series is an excellent source of stable AC voltage over the frequency range of 15 to 1,200 Hz. The output frequency is quartz-crystal stabilized. Output voltages up to 600 VAC are provided.
With the ability to provide singe and three-phase outputs, the ASX Series is the perfect choice to provide 1 Phase to 3 Phase or 3 Phase to 1 Phase conversion.
Six controller models are available with the ASX-Series. They include 1 Phase and 3 Phase models for both manual and programmable control.
All controllers provide manual operation from the front panel. Programmable Controllers may be programmed from the front panel or from a remote interface. RS232 Interface is standard. IEEE 488 interface is optional.
Pacific Power Source offers rugged transit cases to protect your AC Source from adverse environmental conditions for mobile and/or military applications.
Specific benefits:
Available for following ASX models:
Output Frequency:
15 to 1,200 Hz. Full Power
Line Regulation:
0.1% max for a ±10% line change.
Load Regulation:
0.25% 15 to 400 Hz., 0.50% 400 to 1,200 Hz. With external sense enabled. Improves to less than 0.1% with external sense and CSC enabled.
Output Distortion:
0.25% THD 15 to 200 Hz., 0.50% THD 200 to 1,200 Hz.
Ripple and Noise:
-66 dB
Response Time:
60 microseconds typical, 10-90% load step.
All models are designed for operation in 19 inch equipment racks. Models 4 kVA and higher have side handles for ease of handling.
Mounting:
Standard 19 inch rack. Slide rails are available as an option for all models.
Height:
See models table tab for panel height.
Depth:
Approximately 24 inch, from the front panel to the rear of the chassis.
Cooling:
Front or side forced air intake with rear exhaust. Automatic Fan Speed Control for low acoustic noise and extended fan life.
ASX Series Power Sources can be equipped with output transformers to provide an alternate output voltage range. Selection of direct or transformer coupled range is performed by the controller via front panel or bus command. The standard frequency range for transformer coupled outputs is 45 to 1,200 Hz. Standard output ratios are 1.5:1, 2.0:1, and 2.5:1. Transformer outputs are supplied internally or externally via a Magnetics Module as listed in the above table. Consult the factory for additional information regarding special output ranges not listed above.
The latest additions to Pacific’s SmartsourceT family of UPC Controllers are the UPC-1M, UPC-3M, UPC-1 and UPC-3. The UPC Controller is a modular component of the ASX Series and is available in four configurations ranging from 1 Phase to 3 Phase and Manual Control to Programmable Control. The table below lists each model according to key features.
All UPC Controllers include precise metering functions with data displayed via a 160 character LCD display. This, along with the 30-key front panel, provides the industry’s most powerful and user-friendly controller.
The UPC-1 and UPC-3 controllers are available with either the RS-232 or GPIB remote interface. Commands are structured in accordance with SCPI (Standard Commands for Programmable Instruments). The RS-232 serial port operates up to 38.4 Bps. The GPIB interface is compatible with the IEEE-488.2.
Frequency:
Range: 15 to 1,200 Hz.
Resolution: 4 significant digits, eg. 50.00, 400.0, etc.
Accuracy: ±0.01%, 15 to 1,200 Hz
Voltage:
Range: 0 to Vmax in 0.1 VAC steps.
Accuracy: Executive voltage is within ±50 mVAC (0.05%) of command voltage referenced to the internal voltmeter with CSC engaged.
Phase Angle:
Phase Separation of Phases B and C are programmable 0 to 360° relative to phase A on the UPC-3 controller. Phase separation is fixed at 120° and 240°, respectively, on the UPC-3M controller.
Programmable Current Limit:
Programmable Current limit is provided on the UPC-1 and the UPC-3 controllers. Programmable range is from 0 to Ipeak, max of the power source.
Output Voltmeter:
The Output Voltmeter is true RMS reading and each phase is measured independently. Line to neutral and line to line voltages are displayed. Range: 0-354 VACL-N, 0-708 VACL-L. Resolution: 0.1 VAC to front panel, 0.001 VAC to remote interface. Accuracy: ±0.2% of range + cal. ref.
Output Ammeter:
Output Ammeter is true RMS reading and each phase is measured independently. RMS and peak currents along with Crest factor are displayed. Range: 300% of system current rating. Resolution: 0.01 AAC to front panel, 0.001 AAC to remote interface. Accuracy: ±0.2% of range + cal ref.
Power:
Measures True Power (kW), Apparent Power (kVA) and power factor. Range: Based on ammeter. Resolution: 1.0 watts or VA to front panel, 1.0 watts or VA to remote interface.
Power Factor:
Calculated and displayed to three significant digits.
Pacific’s line of Smartsource® AC Power Sources enable the engineer to easily automate his testing by using Lab VIEW for Windows® or LabWindows®. An extensive list of Virtual Instruments (VIs) are offered for Pacific’s ASX Series Power Sources.
![]() 120ASX-UPC3 Power Source |
![]() 315ASX-UPC3 Power Source |
![]() 345ASX-UPC3 Power Source |
![]() 360ASX-UPC3 Power Source |