For questions regarding the AMX Series and or custom solutions, please contact us directly or try our live chat.
Note: The AMX Series products have been discontinued due to parts obsolescence. For new applications or requirements, see the new LMX Series which offer more features and additional remote control interfaces.
When power quality matters, the AMX Series family of High Performance Linear AC Power Sources is the answer. The linear amplifiers within the AMX Series power sources are unmatched in their ability to produce the high crest factor, low-distortion, high fidelity output waveforms required by the most demanding AC Test Power applications. Stand-alone models range from 500 VA to 6 kVA. Larger chassis may be paralleled to create systems that range from 9 to 90 kVA. Offering both single and three phase models, units are conservatively designed with output power ratings are based on the most severe combination of input line, output voltage, power factor, and temperature.
Great emphasis has been placed on low acoustic noise, ease of installation, and safety. Control and operating features provide a high degree of application versatility and ease of use for the test engineer. Applications range from simple, manually controlled frequency conversion to power-line susceptibility testing and sophisticated bus programmable transient simulation.
The exceptionally broad bandwidth (50 kHz small signal), combined with low output impedance and high crest factor ratings give the AMX Series the ability to produce high quality, low distortion output power into the most dynamic loads.
Model | Rated Power (VA) | Output Form | Output Volts-Max (VRMS) | Output Amps (Arms) | Input Power Form | Panel Height (U) | Weight (Lbs./KG) |
---|---|---|---|---|---|---|---|
Single Phase Model | |||||||
105AMX | 500 | 1Ø | 135/270 | 4/2 | 1Ø | 3 | 70/31.8 |
108AMX | 750 | 1Ø | 135/270 | 6/3 | 1Ø | 3 | 70/31.8 |
112AMX | 1200 | 1Ø | 150/300 | 10/5 | 1Ø | 3 | 80/36.3 |
140AMX | 4000 | 1Ø | 135/270 | 32/16 | 3Ø | 8 | 185/84.0 |
160AMX | 6000 | 1Ø | 135/270 | 48/16 | 3Ø | 8 | 195/88.6 |
Three Phase Model | |||||||
305AMX | 500 | 1Ø 3Ø |
135/270 135 (Vl-N) |
4/2 1.3 per Ø |
1Ø | 3 | 74/33.6 |
308AMX | 750 | 1Ø 3Ø |
135/270 135 (Vl-N) |
6/2 2 per Ø |
1Ø | 3 | 74/33.6 |
312AMX | 1200 | 1Ø 3Ø |
150/300 150 (Vl-N) |
10/3.3 3.3 per Ø |
1Ø | 3 | 80/36.3 |
320AMX | 2000 | 1Ø 3Ø |
135/270 135 (Vl-N) |
18/6 6 per Ø |
3Ø | 5 | 150/68.2 |
345AMX | 4500 | 1Ø 3Ø |
135/270 135 (Vl-N) |
36/12 12 per Ø |
3Ø | 8 | 190/86.3 |
360AMX | 6000 | 1Ø 3Ø |
135/270 135 (Vl-N) |
48/16 16 per Ø |
3Ø | 8 | 195/88.6 |
Model | Power (VA) | Form | Output Volts-Max (VRMS) | Output Amps (ARMS) | Power Form | Height (U) |
Weight (Lbs./KG)
|
||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Single Phase Model | |||||||||||||
Transformer | Transformer | ||||||||||||
Direct | 1.5:1 | 2.0:1 | 2.5:1 | Direct | 1.5:1 | 2.0:1 | 2.5:1 | ||||||
105AMXT | 500 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 4/2 | 2.6/1.3 | 2/1 | 1.6/0.8 | 1Ø | 3 |
97/44.0
|
108AMXT | 750 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 6/3 | 4/2 | 3/1.5 | 2.4/1.2 | 1Ø | 3 |
97/44.0
|
140AMXT | 4000 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 32/16 | 21.3/10.7 | 16/8 | 12.8/6.4 | 3Ø | 11 |
310/140.8
|
160AMXT | 6000 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 48/16 | 32/10.7 | 24/8 | 19.2/6.4 | 3Ø | 11 |
320/145.4
|
Three Phase Model | |||||||||||||
Transformer | Transformer | ||||||||||||
Direct | 1.5:1 | 2.0:1 | 2.5:1 | Direct | 1.5:1 | 2.0:1 | 2.5:1 | ||||||
305AMXT |
500
|
1Ø/2Ø
3Ø
|
135/270
135/234
|
202/404
202/350
|
270/540
270/468
|
338/600
338/585
|
4
1.3/Ø
|
2.6/1.3
1.0/Ø
|
2/1
.75/Ø
|
1.6/0.8
0.6/Ø
|
1Ø | 3 |
100/45.5
|
308AMXT |
750
|
1Ø/2Ø
3Ø
|
135/270
135/234
|
202/404
202/350
|
270/540
270/468
|
338/600
338/585
|
6/2
2/Ø
|
4/1.3
1.3/Ø
|
3/1
1/Ø
|
2.4/0.8
0.8/Ø
|
1Ø | 3 |
100/45.5
|
320AMXT |
2000
|
1Ø/2Ø
3Ø
|
135/270
135/234
|
202/404
202/350
|
270/540
270/468
|
338/600
338/585
|
18/6
6/Ø
|
12/4
4/Ø
|
9/3
3/Ø
|
7.2/2.4
2.4/Ø
|
3Ø | 8 |
275/125
|
345AMXT |
4500
|
1Ø/2Ø
3Ø
|
135/270
135/234
|
202/404
202/350
|
270/540
270/468
|
338/600
338/585
|
36/12
12/Ø
|
24/8
8/Ø
|
18/6
6/Ø
|
14.4/4.8
4.8/Ø
|
3Ø | 11 |
315/143.1
|
360AMXT | 6000 |
1Ø/2Ø
3Ø |
135/270
135/234
|
202/404
202/350
|
270/540
270/468
|
338/600
338/585
|
48/16
16/Ø
|
32/10.7
10.7/Ø
|
24/8
8/Ø
|
19.2/6.4
6.4/Ø
|
3Ø | 11 |
320/145.4
|
NOTES
Provides for exceptional accuracy of the AC output Voltage. When enabled, accuracy improves to ±0.03% referenced to the power source internal voltmeter.
Programmable Output Impedance provides the operator with dynamic control over the output impedance of the AC Power Source. Using the output current term as conditioned feedback signal to the output voltage circuits, positive or negative impedance may be programmed. The purpose of this control is to simulate the effects of or compensate for high peak current, distribution, or transformer losses of up to ±10% of the output voltage.
This feature creates positive, negative, or zero output impedance (Zo).
Up to 16 different waveforms can be stored in the waveform library for execution as part of a steady state program or for substitution in any output phase as part of a transient test program. Memory location #1 is a non-editable high resolution sine wave. Locations 2-16 are editable and can be substituted in any output phase. An unlimited number of waveforms may be stored on the computer for those using a programmable UPC.
Provides the ability to modify a stored waveform by specifying the waveform amplitude desired at each specific phase angle.
Provides both a graphic and numeric display of the harmonic structure of a voltage or current waveform. Data presented includes the magnitude of each harmonic in %, the total harmonic distortion, and the odd and even harmonic distortion in %.
Provides the ability to quickly create virtually any AC Test Waveform that may be required by building it out of harmonics. The process is as simple as keying in the harmonic multiple, the amplitude, and the phase angle for each desired harmonic up through the 51st.
Provide the ability to create and execute on command, transients that occur linearly over a specified time segment to modify output voltage or frequency.
Provide the ability to create and execute, on command, transients that substitute a selected waveform in the output for 1 to 100 cycles.
The AMX Series Power Source is equipped with a powerful microcontroller to create a fully integrated test system. It supplies a variety of power conditions to the device under test and meters/analyzes all output performance parameters.
The AMX Series is an excellent source of stable AC voltage over the frequency range of 20 to 5,000 Hz. The output frequency is quartz-crystal stabilized. Output voltages up to 600 VAC are provided.
With the ability to provide single and three-phase outputs, the AMX Series is the perfect choice to provide 1 Phase to 3 Phase or 3 Phase to 1 Phase conversion.
Four controller models are available with the AMX-Series. They include 1 Phase and 3 Phase models for both manual and programmable control.
All controllers provide manual operation from the front panel. Programmable Controllers may be programmed from the front panel or from a remote interface. IEEE 488 interface is standard. RS232 interface is optional.
AMX Series Power Sources can be equipped with output transformers to provide an alternate output voltage range. Selection of direct or transformer coupled range is performed by the controller via front panel or bus command. The standard frequency range for transformer coupled outputs is 45 to 5,000 Hz. Standard output ratios are 1.5:1, 2.0:1, and 2.5:1. Transformer outputs are supplied internally or externally via a Magnetics Module as listed in the above table. Consult the factory for additional information regarding special output ranges not listed above.
Pacific Power Source offers rugged transit cases to protect your AC Source from adverse environmental conditions for mobile and/or military applications.
Specific benefits:
Available for following AMX models:
Output Frequency:
20 to 5000 Hz. Full Power
Line Regulation:
0.1% max for a 10% line change
Load Regulation:
0.25% 20 to 2000 Hz. 0.5% 2000 to 5000 Hz. Can be improved to less than 0.03% with CSC engaged
Output Distortion (Vthd):
3U Models: 15~450 Hz: < 0.1%;
450~5000 Hz: < f x 0.076% + 0.07% (f in kHz)
5U & 8U Models: 45~1,000Hz: < 0.1%
1,000~5,000 Hz: < 0.25%
Ripple and Noise:
< 50 mVrms
Response Time:
5µsec. typical to a step load change. Small signal band-width is 5 Hz. to 50 kHz, typical.
All models are designed for operation in 19 inch equipment racks. Models above 1800 VA have side handles for ease of handling.
Mounting:
Standard 19 inch rack. Slide rails are available as an option for all models.
Height:
See model table above for panel height.
Depth:
Will not exceed 24 inches from the front panel to the rear of the chassis, including connectors, handles and cabling.
Cooling:
Forced air, front or side intakes, rear exhaust with auto fan speed control for low acoustic noise operation.
The UPC controller is essentially a single or three phase AC arbitrary waveform generator and Precision AC metering system. The waveform for each phase may be independently selected and may be independently varied in amplitude and phase angle with respect to phase A (3 phase systems).
The UPC output metering samples the output volts and amps at 512 samples per measurement using a 12 bit A/D converter. This technique provides exceptional metering accuracy and resolution (20 bits), and delivers a high-fidelity waveform back to a host computer for analysis.
The UPC includes a remote GPIB interface compatible with IEEE 488.2 and SCPI. An available option is an RS-232 serial port that operates up to 38.4 kBaud.
Frequency:
20.00 to 5000 Hz ±0.01%
Voltage (Direct):
Programmable, 0-VMAX, in 0.1 volt steps (see table).
Phase Angle:
Phase Angle (f) of Phases B and C relative to Phase A is programmable from 0-359° in 1° increments ± 0.5°.
Current Limit:
Current limit is programmable from 0 to I peak maximum of the power source. Accuracy is ± 1%, resolution ± 0.05%.
Waveform Library:
Stores up to 15 waveforms that can be edited and executed in any manner and in any output phase.
Voltmeter:
Range: 0-354 volts L-N, 0-708 volts L-L
Resolution: 0.10VAC to front panel, 0.001VAC to remote interface
Accuracy: ± 0.25% of reading ± 0.1% of range (50-500Hz)
Ammeter:
Range: 300% of system current rating
Resolution: 0.01AAC to front panel, 0.001AAC to remote interface
Accuracy: ± 0.25% of reading ± 0.1% of range (50-500Hz)
Power Meter:
Range: Based on ammeter range
Resolution: 1.0 watts or VA to front panel, 0.001 Watts or VA to remote interface
Accuracy: ± 1% of Full Scale
Power Factor & Crest Factor:
Calculated and displayed to three significant digits.
![]() 108AMX-UPC3 Power Source |
![]() 308AMX-UPC3 Power Source |
![]() 360AMX-UPC3 Power Source |
![]() 72kVA Three Phase AMX AC Power System |